Power Quality Solution

Harmonic Mitigation Solutions

Reduce Harmonic Distortion. Improve Power Quality.

Harmonics are unwanted electrical distortions generated by modern nonlinear loads like VFDs, UPS systems, rectifiers, and automation electronics. ActiveSine's Active Harmonic Filter (AHF) continuously detects and cancels harmonic currents in real-time, delivering clean sine-wave power and IEEE 519 compliance.

Active Harmonic Filter
ActiveSine AHF Technology

3-Level Topology Active Harmonic Filter

Why Harmonic Mitigation Matters

Nonlinear loads draw current in non-sinusoidal pulses, injecting harmonic frequencies (3rd, 5th, 7th, 11th, etc.) back into your distribution system. Without mitigation, these currents distort the supply voltage.

Overheating & Thermal Stress

Harmonic currents cause severe eddy current and hysteresis losses in transformers, motors, and neutral conductors, leading to premature insulation breakdown.

Nuisance Tripping & Malfunctions

Voltage distortions result in spurious tripping of protective circuit breakers, false sensor triggers, and erratic PLC/automation behavior.

Capacitor Bank Failure & Resonance

Harmonic amplification can trigger parallel and series resonance, catastrophically overloading standard capacitor banks.

Utility Penalty & Non-Compliance

Failure to comply with grid utility harmonic limits (IEEE 519 / CEA standards) leads to heavy penalties and disconnection risks.

How It Works

Active Harmonic Filter (AHF) Closed-Loop Cancellation

ActiveSine AHF acts like noise-canceling headphones for your electrical network. Highly accurate current transformers (CTs) measure harmonic distortion in real-time. The digital signal processor (DSP) analyzes the waveform and commands the 3-level IGBT inverter to inject an equal and opposite anti-harmonic current, restoring the grid current to a pure sine wave.

Dynamic Harmonic Compensation up to 50th Order (Selectable individual harmonics)
Ultra-Fast Response Time (<5ms) for dynamic and nonlinear industrial loads
Simultaneous Power Factor Correction (stepless leading & lagging)
3-Phase 3-Wire and 4-Wire load imbalance & neutral current mitigation
High Filtering Efficiency up to 98% with low thermal losses (<3%)
Advanced 3-Level IGBT topology with intuitive 7”/10” touchscreen HMI
Read Full Technical Specifications for AHF

Technical Performance Summary

Target StandardIEEE 519 / IEC 61000-3-4 / CEA
Harmonic Order Range2nd to 50th Order (Selectable)
Mitigation EfficiencyUp to 98%
Response Time< 5ms (Dynamic Tracking)
Reactive Power CompensationStepless (-0.99 to +0.99 PF)
Topology3-Level IGBT Inverter with DSP

Critical Applications

ActiveSine harmonic mitigation solutions are deployed across diverse demanding industries in India and worldwide.

VFDs & Variable Speed Drives

HVAC systems, pumps, compressors, and crane hoists.

Data Centers & IT Infrastructure

Nonlinear switch-mode power supplies (SMPS) and high-density servers.

Steel, Metallurgy & Arc Furnaces

Extreme nonlinear and cyclically fluctuating heavy industrial loads.

Hospitals & Healthcare

Sensitive imaging systems (MRI, CT scanners) demanding distortion-free power.

Automotive & Robotic Manufacturing

Welding lines, CNC machines, and precision robotic assembly cells.

Process & Chemical Plants

Continuous processes where downtime causes catastrophic batch losses.

Eliminate Harmonics in Your Plant Today

Book an on-site harmonic and power quality audit with our application engineers.